Compliance 101 · Gas, water and electric
EICR and PAT testing
The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require inspection and testing at least every five years where the occupier has the home as their only or main residence. A holiday guest who does not live there is generally outside that definition. HSE says the law does not require a portable appliance test every year.
The rented-home rules
Where the 2020 regulations apply, the landlord must use a qualified person, obtain a report, give a copy to an existing tenant within 28 days, give it to a new tenant before they move in, and complete remedial work within 28 days or any shorter period the report sets. GOV.UK’s holiday-let page still points hosts at that guidance and at HSE’s electrical guidance. Reading it is not the same as the five-year duty applying to every weekend let.
PAT
HSE’s FAQ says the Electricity at Work Regulations 1989 require equipment that could cause injury to be maintained, where those regulations apply. They do not say what must be tested, by whom, or how often, and they do not require an annual test, a label or a written record. A visual check finds many faults. Combined testing is used when the risk justifies it, by someone competent to interpret the results.
Questions
Should I still get an EICR?
Many insurers and fire risk assessments expect the fixed wiring to have been inspected. If you commission a report, follow the next date the competent person writes on it. Do not describe that date as a legal five-year cycle for every holiday let.
Sources
Read next
This is general guidance, not legal advice. Rules differ across England, Scotland, Wales and Northern Ireland, and your property can change what applies. Read the sources on this page, and check with your council or fire and rescue service.